{"product_id":"akw-level-best-stainless-steel-wet-room-waste-tiled-floor","title":"AKW Level Best Stainless Steel Wet Room Waste for Tiled Floors – Choice of TF75, TFWA or SFWA","description":"\u003ch3\u003e\u003cstrong\u003eAKW Level Best Stainless Steel Wet Room Waste for Tiled Floors – Choice of TF75, TFWA or SFWA\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eA tiled wet room deserves a waste that looks the part. AKW’s Level Best stainless steel wastes have a 120 x 120mm stainless steel plate that sits flush with the tiles, and they fit the \u003ca href=\"https:\/\/keywestbathrooms.co.uk\/products\/akw-tuff-form-wet-floor-former\"\u003eAKW Tuff Form\u003c\/a\u003e and \u003ca href=\"https:\/\/keywestbathrooms.co.uk\/products\/akw-tuff-form8-wet-floor-former-all-sizes\"\u003eTuff Form8\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eChoose the stainless steel TF75 for the deepest 75mm water seal (125mm depth below the mounting surface, adjustable elbow for the outlet), the stainless steel TFWA with a GW19 trapped waste (97mm below the former), or one of the waste adaptors without a trap – TFWA or SFWA – if you are supplying your own GW50 or GW19 waste.\u003c\/p\u003e\u003cp\u003eThe plate height adjusts to suit the tile thickness, and every version opens from above for cleaning and rodding. The GW50 versions are \u003ca href=\"https:\/\/keywestbathrooms.co.uk\/products\/akw-ss-tfwa-stainless-steel-waste-adaptor-with-gw50-tiled-floor\"\u003eTFWA with GW50 (LB00102)\u003c\/a\u003e and \u003ca href=\"https:\/\/keywestbathrooms.co.uk\/products\/akw-tuff-form-2-part-gravity-stainless-steel-waste-adaptor-with-gw50-waste-tiled-floors-21318\"\u003eSFWA with GW50 (21318)\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eKey features \u0026amp; benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStainless steel 120 x 120mm plate for tiled wet room floors\u003c\/li\u003e\n\u003cli\u003ePlate height adjusts to suit tile thickness\u003c\/li\u003e\n\u003cli\u003eTF75 with 75mm water seal and adjustable elbow\u003c\/li\u003e\n\u003cli\u003eTFWA with GW19 trapped waste – 97mm below the former\u003c\/li\u003e\n\u003cli\u003eAdaptor-only options (TFWA or SFWA) for your own GW50\/GW19 waste\u003c\/li\u003e\n\u003cli\u003eOpens from above for cleaning and rodding\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoosing a stainless steel waste\u003c\/h2\u003e\u003cp\u003eCheck the depth below the former. The TF75 needs the most (125mm) but gives a 75mm water seal. The TFWA with GW19 needs about 97mm. If depth is very tight, look at the low height DW90 \/ GW90-2 wastes with tiled adaptors instead. Still unsure? Our \u003ca href=\"https:\/\/keywestbathrooms.co.uk\/blogs\/advice-and-guides\/which-wet-room-waste-do-i-need-complete-guide-akw-shower-wastes\"\u003ecomplete guide to AKW wet room wastes\u003c\/a\u003e explains how to choose by floor finish and depth below the former, and our team can check your layout on 0333 772 4162.\u003c\/p\u003e\u003ch2\u003eInstallation notes\u003c\/h2\u003e\u003cp\u003eFit before tiling. Bed the plate at the finished tile height using the adjustment, connect the outlet with a continuous fall, and seal into the tanking with a Mapeband waste outlet gasket.\u003c\/p\u003e\u003ch2\u003eSizes \u0026amp; product codes\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWaste\u003c\/th\u003e\n\u003cth\u003eAKW code\u003c\/th\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless Steel TF75 Waste (LB00101)\u003c\/td\u003e\n\u003ctd\u003eLB00101\u003c\/td\u003e\n\u003ctd\u003e5055295109223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless Steel TFWA Waste with GW19 Trapped Waste (LB00103)\u003c\/td\u003e\n\u003ctd\u003eLB00103\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless Steel TFWA Waste Adaptor without Trapped Waste (LB00171)\u003c\/td\u003e\n\u003ctd\u003eLB00171\u003c\/td\u003e\n\u003ctd\u003e5055295109230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless Steel SFWA Waste Adaptor without Trapped Waste (25433)\u003c\/td\u003e\n\u003ctd\u003e25433\u003c\/td\u003e\n\u003ctd\u003e5055295150522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eTechnical specification\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003ctd\u003e120 x 120mm stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLB00101\u003c\/td\u003e\n\u003ctd\u003eStainless steel TF75 – 125mm below mounting surface, 75mm water seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLB00103\u003c\/td\u003e\n\u003ctd\u003eStainless steel TFWA with GW19 trapped waste – 128mm overall, 97mm below former\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLB00171 \/ 25433\u003c\/td\u003e\n\u003ctd\u003eStainless steel TFWA \/ SFWA adaptor without trapped waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor finish\u003c\/td\u003e\n\u003ctd\u003eTiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eAKW Tuff Form and Tuff Form8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAKW Level Best\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003ch3\u003eCan I use these with vinyl?\u003c\/h3\u003e\u003cp\u003eNo – these are for tiled floors. For vinyl choose the TF75 or TFWA vinyl wastes.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between TFWA and SFWA?\u003c\/h3\u003e\u003cp\u003eBoth are AKW stainless steel waste adaptors for tiled floors that take a trapped waste. The SFWA is the dot-grate version that AKW pair with GW50 or GW19 wastes in their 21318 and 21319 sets.\u003c\/p\u003e\u003ch3\u003eDoes the adaptor-only version include a trap?\u003c\/h3\u003e\u003cp\u003eNo – add a GW50 or GW19 trapped waste.\u003c\/p\u003e\u003ch2\u003eDownloads\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/akw-ltd.co.uk\/wp-content\/uploads\/2021\/08\/tf75wastespecification.pdf\"\u003eTF75 waste specification sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eNot sure which part you need? Call our team on \u003cstrong\u003e0333 772 4162\u003c\/strong\u003e and we will check it against your installation before you order.\u003c\/p\u003e","brand":"AKW","offers":[{"title":"Stainless Steel TF75 Waste (LB00101)","offer_id":57588402651462,"sku":"LB00101","price":116.95,"currency_code":"GBP","in_stock":true},{"title":"Stainless Steel TFWA Waste with GW19 Trapped Waste (LB00103)","offer_id":57588402684230,"sku":"LB00103","price":96.22,"currency_code":"GBP","in_stock":true},{"title":"Stainless Steel TFWA Waste Adaptor without Trapped Waste (LB00171)","offer_id":57588402716998,"sku":"LB00171","price":86.5,"currency_code":"GBP","in_stock":true},{"title":"Stainless Steel SFWA Waste Adaptor without Trapped Waste (25433)","offer_id":57588402749766,"sku":"25433","price":84.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0961\/7273\/6838\/files\/Screenshot_2024-10-31_090202.png?v=1759761237","url":"https:\/\/www.keywestbathrooms.co.uk\/products\/akw-level-best-stainless-steel-wet-room-waste-tiled-floor","provider":"Key West Bathrooms","version":"1.0","type":"link"}